Kit SP24 Axpert VM III 5.0Kw 48V Off-Grid Inverter + 2 Yilink 50AH 48V Batteries total 4.8Kw storage

0 out of 5

1.485,00

SKU: N/A Categories: ,

Description

Kit SP24 Axpert VM III 5.0Kw 48V Off-Grid Inverter and 2 x Yilink 50AH 48V Batteries Total 4.8Kw Storage

SP24 Axpert Primo VM III (PF1) 5Kw 48 Volt 5000-48 Off-Grid Island Solar Inverter

– Alternating Current Power 5kw
– Installed Power Panels 5kw
– 48V battery pack support
• Removable LCD control module with multiple communications
• Integrated Bluetooth for mobile monitoring (Android app available)
• Supports USB On-the-Go function
– Reserved communication port for BMS (RS485, CAN-BUS or RS232) support x Pylontech, SP24 all, others
• Replaceable fan design for ease of maintenance
• Supply the load from the grid or the PV, even if the battery is not available
• Use timer and priority of AC / PV configurable outputs
– Selectable high-power charge current
• Selectable input voltage range for household appliances and personal computers
• Compatible with mains supply or generator input
• Automatic restart while AC is recovering
• Cold start function

INVERTER MODEL

 

 

1.5KW

 

 

3KW

 

 

5KW

 

 

Input voltage waveform

 

 

Sinusoidal(AC mains or generator)

Rated input voltage

 

 

230Vac

Low voltage loss

 

 

170Vac ± 7V (UPS);

90Vac ± 7V (equipment)

Low return voltage loss

 

 

180Vac ± 7V (UPS);

100Vac ± 7V (Appliances)

High voltage loss

 

 

280Vac ± 7V

High return voltage loss

 

 

270Vac ± 7V

Max. AC input voltage

 

 

300Vac

Rated input frequency

 

 

50Hz / 60Hz (Auto detection)

Low frequency loss

 

 

40 ± 1 Hz

Low return frequency loss

 

 

42 ± 1 Hz

High frequency loss

 

 

65 ± 1 Hz

 

 

High return frequency loss

 

 

63 ± 1 Hz

Short circuit protection at the output

 

 

Differential switch

Efficiency (Line Mode)

 

 

>95% (nominal R load, fully charged battery)

Transfer duration

 

 

10ms typical (UPS);

20ms typical (appliances);

Reduction of output power

 

 

If the AC input voltage drops to 170V, the output power will be reduced.

INVERTER MODEL

 

 

1.5KW

 

 

3KW

 

 

5KW

 

 

Rated output power

 

 

1.5KVA / 1.5KW

3KVA / 3KW

5KVA / 5KW

Output voltage waveform

 

 

Pure sine wave

Output voltage regulation

 

 

230Vac ± 5%

Output frequency

 

 

50 Hz

Peak efficiency

 

 

93%

Overload protection

 

 

5s @ ≥130% load; 10s @ 105 %~130% load

Overload capacity

 

 

2 * Rated power for 5 seconds

Nominal DC input voltage

 

 

24Vdc

48Vdc

Cold start voltage

 

 

23.0Vdc

46.0Vdc

DC Low Voltage alarm

 

 

@ load< 50%

23.0Vdc

46.0Vdc

@ load ≥ 50%

22.0Vdc

44.0Vdc

DC Low Return Voltage Alarm

 

 

@ load< 50%

23.5Vdc

47.0Vdc

@ load ≥ 50%

23.0Vdc

46.0Vdc

DC Low Voltage cutoff

 

 

@ load< 50%

21.5Vdc

43.0Vdc

@ load ≥ 50%

21.0Vdc

42.0Vdc

DC High Recovery Voltage

 

 

32Vdc

62Vdc

DC High Cutoff Voltage

 

 

33Vdc

63Vdc

Consumption without load

 

 

<35W

<50W

AC network charging mode

 

 

INVERTER MODEL

 

 

1.5KW

 

 

3KW

 

 

5KW

 

 

Charging algorithm

 

 

3-Step

 

 

Charging current AC (max.)

 

 

40Amp (@V I / P = 230Vac)

60Amp

(@V I / P = 230Vac)

Bulk charge voltage

 

 

Flooded battery

 

 

29,2

58,4

AGM / Gel battery

 

 

28,2

56,4

Float voltage

 

 

27Vdc

54Vdc

Charge curve

 

 

MPPT Solar Charge Mode

INVERTER MODEL

 

 

1.5KW

 

 

3KW

 

 

5KW

 

 

Max. PV array power

 

 

2000 W

4000W

5000W

Nominal PV voltage

 

 

240Vdc

320Vdc

Inrush voltage

 

 

150Vdc +/- 10Vdc

PV array MPPT voltage range

 

 

120 ~ 380Vdc

120 ~ 450Vdc

Max. PV array open circuit voltage

 

 

400Vdc

500Vdc

Maximum charge current

 

 

(AC charger plus solar charger)

 

 

60A

80Amp

INVERTER MODEL

 

 

1.5KW

 

 

3KW

 

 

5KW

 

 

Operating temperature range

 

 

– 10 ° C + 50 ° C

Storage temperature

 

 

-15 ° C ~ 60 ° C

Humidity

 

 

5 – 95% relative humidity (non-condensing)

Dimensions (P * W * H), mm

 

 

100 x 280 x 390

115 x 300 x 400

Net weight, kg

 

 

8,5

9

10

 

Battery Pack Parameters

No.

 

 

Items

 

 

General Parameter

 

 

Remark

 

 

1

Combination method

15S

2

Nominal Voltage

48V

 

3

 

Rated Capacity

Typical

50Ah

Minimum

50Ah

4

Energy

2400Wh

5

Factory Voltage

48~51V

Mean Operation Voltage

6

Voltage at end of Discharge

37.5~42V

Discharge Cut-off Voltage

7

Voltage at end of Charge

52.5~55.5V

Charge Cut-off Voltage

 

8

 

 

Standard charge

Constant Current 10A Constant Voltage see No.7

0.02CA cut-off

 

Charge time : Approx 5~6 h

9

 

Limiting current

20A

BMS Limited (Charge current is

≥50A to open the current Limit)

10

Standard discharge

Constant current:10A end voltage see NO.6

11

Maximum Continuous Charge Current

50A

50ºC≥T≥5ºC

12

Maximum Continuous Discharge Current

50A

55ºC≥T≥0ºC

 

 

 

13

 

 

Operation Temperature Range

Charge:0~55℃

60±25%R.H.

No matter what mode the battery is in, once the temperature is found to exceed the absolute temperature range, stop charging or discharging immediately

 

 

Discharge:20~60℃

 

 

14

 

 

Storage Temperature Range

Less than 6 months: -10~35℃

 

60±25%R.H.

at the shipment state

Less than 3 months: -10~45℃

Less than 1 months: -20~55℃

15

Dimensions(W*D*H)

442*480*133mm

Include case

16

Net Weight

27Kg

Include case

 

 

 

 

17

 

 

 

 

Internal Impedance

 

 

 

≤50mΩ

Internal resistance measured at AC 1KHZ after 50% charge.

The measure must uses the new batteries that within one week after shipment and cycles less than 5

times.

Battery Management System

 

Function

 

 

 

 

 

 

 

Alarm

Cell over-charge voltage

Cell charge low temperature

Cell over-discharge voltage

Cell charge over temperature

Pack over-charge voltage

Cell discharge low temperature

Pack over-discharge voltage

Cell discharge over temperature

Over-current charge

Environment low temperature

Over-current discharge

Environment over temperature

Mos over temperature

 

 

 

 

 

Protection

Cell over-charge voltage

Cell charge over temperature

Cell over-discharge voltage

Cell discharge low temperature

Pack over-charge voltage

Cell discharge over temperature

Pack over-discharge voltage

Environment low temperature

Over-current charge

Environment over temperature

Over-current discharge

Short circuit

Mos over temperature

Fault

Cell charge low temperature

 

 

 

 

Others

Cell balance function

Communicate function

Total capacity function

Storage history function

Current limiting function

Dry contact function

No.

 

 

Items

 

 

Description

 

 

1

+ Power terminal

Power cable terminals: one connect to equipment, the other one paralleling to other battery module for capacity

expanding.

2

Power terminal

3

LCD Screen

Display the battery’s data

4

Power Switch

To turn ON/OFF while battery.

5

Working indicator light

Display state information.

6

ALM alarm indicator light

Red-trouble-light on.

7

Capacity volume indicator

Display the battery’s capacity.

8

Reset Key

Sleep /Activation /Reset.

9

ADS Dialer

4 ADD switches, to define different address code for each

battery module when multiple modules are cascaded, up to 15 addresses

10

Dry Contact Terminal

1/2 Normally open, closed during fault protection;

3/4 Normally open, closed when a low battery alarm

11

RS485

RJ45 Port,used to connect to the inverter’s RS485 port

12

CAN

RJ45 Port,used to connect to the inverter’s CAN port

13

RS232

RJ11 Port,used battery condition monitoring or manufacturer to

debug or service

14

RS485

RJ45 Port,used communication in parallel

15

Grounding Point

Safety

 

 

Additional information

Weight 120 kg
Vat Rate

,