SP24 Axpert Max II 10Kw 48 10000 Watt 48 Volt Off Grid Island Solar Inverter
€893,20
– Status indication with RGB lights
– Single phase with dual 5000 Watt MPPT regulator
– Built-in Wi-Fi for mobile monitoring (Android / iOS app available)
– Communication with BMS protocols Pylontech, Luxpower, Ufo Battery, Yilink
– Reserved communication port for BMS RS485
– Replaceable fan design for ease of maintenance
– Battery-independent design
– Configurable AC / PV output timer and utilization priority
– Selectable high-power charge current
– Selectable input voltage range for home appliances and personal computers
– Compatible with mains or generator input
– Built-in dust kit
– Possibility of parallel operation with 6 units in single/three-phase configuration
- Description
- Additional information
- Download Documents
Description
|
MODEL |
10KW |
|
Input voltage waveform |
Sinusoidal (AC mains or generator) |
|
Rated input voltage |
230Vac |
|
Low voltage loss |
170Vac ± 7V (UPS) 90Vac ± 7V (equipment) |
|
Low Return Voltage Drop |
180Vac ± 7V (UPS); 100Vac ± 7V (Equipment) |
|
High Voltage Drop |
280Vac ± 7V |
|
High Return Voltage Drop |
270Vac ± 7V |
|
Max. AC input voltage |
300Vac |
|
Current Max. AC input |
60A |
|
Rated input frequency |
50Hz / 60Hz (Auto Detect) |
|
Low Frequency Drop |
40 ± 1Hz |
|
Low Return Voltage Drop |
42 ± 1Hz |
|
High Frequency Drop |
65 ± 1Hz |
|
High Return Voltage Drop |
63 ± 1Hz |
|
Short circuit protection at the output |
Line Mode: RCD (70A) Battery mode: Electronic Circuits |
|
Efficiency (Line Mode) |
>95% (Rated load R, battery fully charged) |
|
Transfer duration |
10ms typical (UPS); 20ms typical (equipment); |
|
Output power reduction: If the AC input voltage drops below 170V, the output power will be reduced. |
|
|
MODEL |
10KW |
|
Rated output power |
10000W |
|
Output voltage waveform |
Pure sine wave |
|
Output voltage regulation |
230Vac ± 5% |
|
Output frequency |
60Hz or 50Hz |
|
Peak efficiency |
93% |
|
Overload protection |
100ms @ ≥205% load; 5s @ ≥150% load; 10s @ 110 %~150% load |
|
Overload capacity |
2 * Rated power for 5 seconds |
|
Low DC alarm voltage |
46.0Vdc 42.8Vdc 40.4Vdc
|
|
@ load< 20% @ 20% ≤ load< 50% @ load ≥ 50% |
|
|
Low DC Alarm Return Voltage |
48.0Vdc 44.8Vdc 42.4Vdc
|
|
@ load< 20% @ 20% ≤ load< 50% @ load ≥ 50% |
|
|
Low DC cutoff voltage |
44.0Vdc 40.8Vdc 38.4Vdc
|
|
@ load< 20% @ 20% ≤ load< 50% @ load ≥ 50% |
|
|
High recovery DC voltage |
61Vdc |
|
High DC cutoff voltage |
63Vdc |
|
DC voltage accuracy |
|
|
THDV |
<5% for linear load,< 10% for non-linear load @ rated voltage |
|
DC offset |
≦ 100mV |
|
Consumption without load |
<75W |
|
AC Grid Load Mode |
|||
|
MODEL |
10KW |
||
|
Charging current (UPS) @ Nominal input voltage |
150A (@V I / P = 230Vac) |
||
|
Bulk Charge Voltage |
Lead-acid battery |
58.4Vdc |
|
|
AGM / Gel battery |
56.4Vdc |
||
|
Charging float voltage |
54Vdc |
||
|
Overload protection |
63Vdc |
||
|
Charging algorithm |
3 step |
||
|
Charge curve |
|
||
|
Solar entrance |
|||
|
MODEL |
10KW |
||
|
Nominal power |
10000W |
||
|
Max. PV array open circuit voltage |
500Vdc |
||
|
PV array MPPT voltage range |
90Vdc ~ 450Vdc |
||
|
Max. Input current |
18A x 2 |
||
|
Starting voltage |
80V +/- 5Vdc |
||
|
Power limitation |
|||

Table 4 General Specifications
|
MODEL |
10KW |
|
Safety certification |
THERE IS |
|
Operating temperature range |
– 10 ° C + 50 ° C |
|
Storage temperature |
-15 ° C ~ 60 ° C |
|
Humidity |
5 – 95% relative humidity (non-condensing) |
|
Dimensions (P * W * H), mm |
158.4x 503.6 x 530.8 |
|
Net weight, kg |
20 |
Table 5 Parallel Specifications
|
Nr. max. in parallel |
6 |
|
Circulation current under no-load conditions |
Max. 2A |
|
Power imbalance ratio |
<5% @ 100% load |
|
Parallel communication |
CAN |
|
Transfer time in parallel mode |
Max.50ms |
|
Parallel Kit |
YES |
Note: The parallel function will be disabled if only PV power is available
Download Documents
Manual Max II 10Kw ITA
Manual Max II 10Kw EN