SP24 Axpert VM IV TWIN 4Kw 24V 4000-24 Inverter Solar Island Off Grid
Product RIGENERATED 12 months warranty
– Alternating Current Power 4kw
– Installed Power Panels 5kw
• Support for 24V battery packs
• Removable LCD control module with multiple communications
– Built-in Wi-Fi for mobile monitoring (Android/Iphone app available)
• Supports USB On-the-Go function
– Reserved communication port for BMS (RS485) support x Pylontech UP2500, Yilink 100Ah 24v
• Replaceable fan design for ease of maintenance
• Supply the load from the grid or the PV, even if the battery is not available
• Use timer and priority of AC / PV configurable outputs
– Selectable high-power charge current
• Selectable input voltage range for household appliances and personal computers
• Compatible with mains supply or generator input
• Automatic restart while AC is recovering
• Cold start function
SPECIFICATIONS
Table 1 Line Mode Specifications
|
MODEL |
4KW |
6KW |
|
Input Voltage Waveform |
Sinusoidal (utility or generator) |
|
|
Nominal Input Voltage |
230Vac |
|
|
|
170Vac±7V (UPS); 90Vac±7V (Appliances) |
|
|
|
180Vac±7V (UPS); 100Vac±7V (Appliances) |
|
|
|
280Vac±7V |
|
|
|
270Vac±7V |
|
|
Max AC Input Voltage |
300Vac |
|
|
Nominal Input Frequency |
50Hz / 60Hz (Auto detection) |
|
|
|
40 ± 1Hz |
|
|
|
42 ± 1Hz |
|
|
|
65 ± 1Hz |
|
|
|
63 ± 1Hz |
|
|
Output Short Circuit Protection |
Circuit Breaker |
|
|
Efficiency (Line Mode) |
>95% ( Rated R load, battery full charged ) |
|
|
Transfer Time |
10ms typical (UPS); 20ms typical (Appliances) |
|
|
Output power derating: When AC input voltage drops to 170V, the output power will be derated. |
|
|
Table 2 Inverter Mode Specifications
|
MODEL |
4KW |
6KW |
|
Rated Output Power |
4KVA/4KW |
6KVA/6KW |
|
Output Voltage Waveform |
Pure Sine Wave |
|
|
Output Voltage Regulation |
230Vac±10% |
|
|
Output Frequency |
50Hz |
|
|
|
93% |
|
|
|
5s@≥110% load; 10s@105~110 load |
|
|
|
2* rated power for 5 seconds |
|
|
Max. AC Output Current |
30Amp |
40Amp |
|
Nominal DC Input Voltage |
24Vdc |
48Vdc |
|
Cold Start Voltage |
23.0Vdc |
46.0Vdc |
|
Low DC Warning Voltage |
|
|
|
@ load < 50% |
23.0Vdc |
46.0Vdc |
|
@ load ≥ 50% |
22.0Vdc |
44.0Vdc |
|
Low DC Warning Return Voltage |
|
|
|
@ load < 50% |
23.5Vdc |
47.0Vdc |
|
@ load ≥ 50% |
23.0Vdc |
46.0Vdc |
|
|
|
|
|
@ load < 50% |
21.5Vdc |
43.0Vdc |
|
@ load ≥ 50% |
21.0Vdc |
42.0Vdc |
|
|
32Vdc |
62Vdc |
|
|
33Vdc |
63Vdc |
|
No Load Power Consumption |
<40W |
<55W |
Table 3 Charge Mode Specifications
|
Utility Charging Mode |
|||
|
MODEL |
4KW |
6KW |
|
|
@ Nominal Input Voltage |
100Amp (@V I / P = 230Vac) |
||
|
Bulk Charging Voltage |
Flooded Battery |
29.2 |
58.4Vdc |
|
|
28.2 |
56.4Vdc |
|
|
Floating Charging Voltage |
27Vdc |
54Vdc |
|
|
Charging Algorithm |
3-Step |
||
|
Charging Curve |
|
||
|
Solar Input |
|||
|
MODEL |
4KW |
6KW |
|
|
Max. PV Array Power |
5000W |
6000W |
|
|
Max. PV Current |
27A |
||
|
Nominal PV Voltage |
320Vdc |
360Vdc |
|
|
Start-up Voltage |
60Vdc +/- 10Vdc |
||
|
PV Array MPPT Voltage Range |
60Vdc~450Vdc |
||
|
Max. PV Array Open Circuit Voltage |
500Vdc |
||
|
Max Charging Current (AC charger plus solar charger) |
120Amp |
||
Table 4 General Specifications
|
MODEL |
4KW |
6KW |
|
Operating Temperature Range |
-10°C to 50°C |
|
|
Storage temperature |
-15 ° C ~ 60 ° C |
|
|
|
5% to 95% Relative Humidity (Non-condensing) |
|
|
|
119 x 313.6 x 457.5 |
|
|
Net Weight, kg |
10 |
12 |