Description

SP24 Axpert Max II 11Kw Twin 11000 Watt 48 Volt Off Grid Island Solar Inverter Kit
+ 2 UFO Power WALL LifePO4 200ah 48 volt 9.6kw batteries (tot 19.2 kw)

 

INVERTER SPECIFICATIONS

Table 1 Line mode specifications

MODEL

11 kW

Input voltage waveform

Sinusoidal (service or generator)

Rated input voltage

230Vac


Low

loss

Voltage

170Vac± 7V ( UPS )

90Vac± 7V ( Household appliances )


Low

loss

Return voltage

180Vac ± 7V ( UPS ) ;

100Vac ± 7V ( Household appliances )

High loss Voltage

280Vac± 7V

High loss Return voltage

270Vac± 7V

Maximum AC input voltage

300 V AC

Maximum AC input current

60A


Maximum
2a output current

40A

Nominal input frequency

50Hz / 60Hz (automatic detection)


Low frequency

of loss

40 ± 1Hz


Low

loss

Frequency

of return

42 ± 1Hz


High frequency

of loss

65 ± 1Hz

High loss Frequency of return

63 ± 1Hz

Output short circuit protection

Line Mode: Circuit Breaker (70A)

Battery mode: electronic circuits

Efficiency (line mode)

>95% (rated R load, fully charged battery)

Transfer time

10 ms typical (UPS);

20 ms typical (Household appliances)

Reduction in output power:

When the AC input voltage is less than 170V, the output power will be reduced.

 

Table 2 Specifications of the inverter mode

MODEL

11 kW

Rated output power

11000W

Output voltage waveform

Pure sine wave

Adjusting the output voltage

230Vac± 5 %

Output frequency

60Hz or 50Hz

Efficiency maximum

93%

Protection from overload

100 ms at ≥180% load ; 5 s at ≥120% load ; 10 s at 105%~120% load

Overvoltage capability

Rated power 2* for 5 seconds

Optional 12V DC output

DC output

12 VDC ± 7%, 100 W

High DC interruption voltage

6 3 VDC

Low DC interruption voltage

44 VDC

Nominal DC input voltage

48 V cc

Cold start voltage

46 .0 VDC

DC low voltage warning

@ load< 20%

46 .0 VDC

@ 20% ≤ load< 50%

42 . 8 Vcc

@ load ≥ 50%

40 . 4 Vcc

Low DC warning return voltage

@ load< 20%

48 .0 VDC

@ 20% ≤ load< 50%

44 . 8 Vcc

@ load ≥ 50%

42 . 4 Vcc


Low

DC interruption voltage

@ load< 20%

44 .0 VDC

@ 20% ≤ load< 50%

40 . 8 Vcc

@ load ≥ 50%

38 . 4 Vcc

High current continuous Recovery voltage

61 Vcc

High DC interruption voltage

6 3 Vcc

DC voltage accuracy

+/-0.3 V at no load

THDV

<5% for linear load, <10% for nonlinear load at rated voltage

Offset CC

100 mV

Power limitation

When the battery voltage is less than 55 V DC , the output power will be derated . If the connected load is higher than this derated power , the AC output voltage will decrease until the output power is reduced to this derated power . The minimum AC output voltage is set to. 1 0 V.

Table 3 Specifications of charging mode

Utility charging mode

MODEL

11 kW

Charging current (UPS)

@ Rated input voltage

15 0 A

Bulk charge voltage

Flooded battery

58.4 VDC

Battery AGM / Gel

56.4 VDC

Floating charge voltage

54 VDC

Overload protection

63 VDC

Charging algorithm

3 -Phase

Charging curve

Solar entrance

MODEL

11 kW

Nominal power

1100 0W

Maximum open circuit voltage of the photovoltaic array

500 VDC

MPPT voltage range of the photovoltaic array

90 VDC~450 VDC

Maximum input current

27A x 2 (MAX 40A)

Maximum charge current

1 50A

Starting voltage

80 V +/- 5 VDC

Power limitation

Table 4 General Specifications

MODEL

11 kW

Safety certification

THERE IS

Operating temperature range

from -1 0°C to 50°C

Storage temperature

-15°C~60°C

Moisture

Relative humidity from 5% to 95% (no condensation)

Size

( P *L*A) , mm

147.4x 432.5x 553.6

Net weight, kg

18.4

Table 5 Parallel specifications

Maximum number of parallel numbers

6

Circulating current under no-load condition

Maximum 2A

Power imbalance ratio

<5% at 100% load

Parallel communication

POWER

Parallel mode transfer time

Maximum 50 ms

Parallel kit

YES

Note: The parallel function will be disabled when only PV power is available.

UFO Power Wall LifePO4 200Ah 48V 9.6Kw Battery for Solar Photovoltaic Systems

High qualitylithium solar battery, UFO lithium solar battery is a deep cycle battery with over 6000 life cycles at 80% DOD. Intelligent battery management system Up to 15 lithium solar batteries in parallel for increased energy storage. Connection of up to 15 lithium batteries is supported for the solar energy storage system.


-battery with multiprotocol BMS for inverters of multiple brands including SP24, Voltronic (LIB protocol), Pylontech protocol both RS485 and CAN
here is the complete list

Model of battery pack

 

 

WL-P48200

 

 

Nominal voltage

LFP battery 48V

Rated capacity

200AH

Rated reserved energy

9600WH

Standard charging current

0.2C

Total charging cut-off voltage

52.50V

Cut-off voltage of charging monomer

3.5V

Standard discharging current

0.2C

Maximum continuous discharging current

100A

Cut-off voltage of discharging monomer

2.5V

Charging temperature range

-5℃~55

Discharging temperature range

-20℃~65

Dimension (W×D×H)

490*650*250mm

(excluding hanger and Anderson connector)

Weight

95kg

Compound mode

15 strings

Storage temperature

0℃~40℃

 

 

Differential pressure

Differential pressure at the discharging end (2.5V for monomer) ≤300mV

Differential pressure at the charging end (3.65V for monomer≤300mV

Additional information

Weight 25 kg
Aliquota Iva

,

Download Documents

Manual SP24_Infinisolar_V_IV_TWIN_6Kw_ITA


Manual SP24 Infinisolar V IV TWIN 6Kw ENG

 

Reviews

There are no reviews yet.


Be the first to review “SP24 Axpert Max II 11Kw Twin 11000 Watt 48 Volt Off Grid Solar Island Inverter Kit + 2 UFO Power WALL LifePO4 200ah 48 volt 9.6kw Batteries (tot 19.2 kw)”