INVERTER SPECIFICATIONS
Table 1 Line mode specifications
|
MODEL |
11 kW |
|
Input voltage waveform |
Sinusoidal (service or generator) |
|
Rated input voltage |
230Vac |
|
|
170Vac± 7V ( UPS ) 90Vac± 7V ( Household appliances ) |
|
|
180Vac ± 7V ( UPS ) ; 100Vac ± 7V ( Household appliances ) |
|
High loss Voltage |
280Vac± 7V |
|
High loss Return voltage |
270Vac± 7V |
|
Maximum AC input voltage |
300 V AC |
|
Maximum AC input current |
60A |
|
|
40A |
|
Nominal input frequency |
50Hz / 60Hz (automatic detection) |
|
|
40 ± 1Hz |
|
|
42 ± 1Hz |
|
|
65 ± 1Hz |
|
High loss Frequency of return |
63 ± 1Hz |
|
Output short circuit protection |
Line Mode: Circuit Breaker (70A) Battery mode: electronic circuits |
|
Efficiency (line mode) |
>95% (rated R load, fully charged battery) |
|
Transfer time |
10 ms typical (UPS); 20 ms typical (Household appliances) |
|
Reduction in output power: When the AC input voltage is less than 170V, the output power will be reduced. |
|
Table 2 Specifications of the inverter mode
|
MODEL |
11 kW |
|
Rated output power |
11000W |
|
Output voltage waveform |
Pure sine wave |
|
Adjusting the output voltage |
230Vac± 5 % |
|
Output frequency |
60Hz or 50Hz |
|
Efficiency maximum |
93% |
|
Protection from overload |
100 ms at ≥180% load ; 5 s at ≥120% load ; 10 s at 105%~120% load |
|
Overvoltage capability |
Rated power 2* for 5 seconds |
|
Optional 12V DC output |
|
|
DC output |
12 VDC ± 7%, 100 W |
|
High DC interruption voltage |
6 3 VDC |
|
Low DC interruption voltage |
44 VDC |
|
Nominal DC input voltage |
48 V cc |
|
Cold start voltage |
46 .0 VDC |
|
DC low voltage warning |
|
|
@ load< 20% |
46 .0 VDC |
|
@ 20% ≤ load< 50% |
42 . 8 Vcc |
|
@ load ≥ 50% |
40 . 4 Vcc |
|
Low DC warning return voltage |
|
|
@ load< 20% |
48 .0 VDC |
|
@ 20% ≤ load< 50% |
44 . 8 Vcc |
|
@ load ≥ 50% |
42 . 4 Vcc |
|
|
|
|
@ load< 20% |
44 .0 VDC |
|
@ 20% ≤ load< 50% |
40 . 8 Vcc |
|
@ load ≥ 50% |
38 . 4 Vcc |
|
High current continuous Recovery voltage |
61 Vcc |
|
High DC interruption voltage |
6 3 Vcc |
|
DC voltage accuracy |
+/-0.3 V at no load |
|
THDV |
<5% for linear load, <10% for nonlinear load at rated voltage |
|
Offset CC |
≦ 100 mV |
|
Power limitation When the battery voltage is less than 55 V DC , the output power will be derated . If the connected load is higher than this derated power , the AC output voltage will decrease until the output power is reduced to this derated power . The minimum AC output voltage is set to. 1 0 V. |
|
Table 3 Specifications of charging mode
|
Utility charging mode |
|||
|
MODEL |
11 kW |
||
|
Charging current (UPS) @ Rated input voltage |
15 0 A |
||
|
Bulk charge voltage |
Flooded battery |
58.4 VDC |
|
|
Battery AGM / Gel |
56.4 VDC |
||
|
Floating charge voltage |
54 VDC |
||
|
Overload protection |
63 VDC |
||
|
Charging algorithm |
3 -Phase |
||
|
Charging curve |
|
||
|
Solar entrance |
|||
|
MODEL |
11 kW |
||
|
Nominal power |
1100 0W |
||
|
Maximum open circuit voltage of the photovoltaic array |
500 VDC |
||
|
MPPT voltage range of the photovoltaic array |
90 VDC~450 VDC |
||
|
Maximum input current |
27A x 2 (MAX 40A) |
||
|
Maximum charge current |
1 50A |
||
|
Starting voltage |
80 V +/- 5 VDC |
||
|
Power limitation |
|
||
Table 4 General Specifications
|
MODEL |
11 kW |
|
Safety certification |
THERE IS |
|
Operating temperature range |
from -1 0°C to 50°C |
|
Storage temperature |
-15°C~60°C |
|
Moisture |
Relative humidity from 5% to 95% (no condensation) |
|
Size ( P *L*A) , mm |
147.4x 432.5x 553.6 |
|
Net weight, kg |
18.4 |
Table 5 Parallel specifications
|
Maximum number of parallel numbers |
6 |
|
Circulating current under no-load condition |
Maximum 2A |
|
Power imbalance ratio |
<5% at 100% load |
|
Parallel communication |
POWER |
|
Parallel mode transfer time |
Maximum 50 ms |
|
Parallel kit |
YES |
Note: The parallel function will be disabled when only PV power is available.
UFO Power Wall LifePO4 200Ah 48V 9.6Kw Battery for Solar Photovoltaic Systems
High qualitylithium solar battery, UFO lithium solar battery is a deep cycle battery with over 6000 life cycles at 80% DOD. Intelligent battery management system Up to 15 lithium solar batteries in parallel for increased energy storage. Connection of up to 15 lithium batteries is supported for the solar energy storage system.

-battery with multiprotocol BMS for inverters of multiple brands including SP24, Voltronic (LIB protocol), Pylontech protocol both RS485 and CAN
here is the complete list
|
Model of battery pack
|
WL-P48200
|
|
Nominal voltage |
LFP battery 48V |
|
Rated capacity |
200AH |
|
Rated reserved energy |
9600WH |
|
Standard charging current |
0.2C |
|
Total charging cut-off voltage |
52.50V |
|
Cut-off voltage of charging monomer |
3.5V |
|
Standard discharging current |
0.2C |
|
Maximum continuous discharging current |
100A |
|
Cut-off voltage of discharging monomer |
2.5V |
|
Charging temperature range |
-5℃~55℃ |
|
Discharging temperature range |
-20℃~65℃ |
|
Dimension (W×D×H) |
490*650*250mm (excluding hanger and Anderson connector) |
|
Weight |
95kg |
|
Compound mode |
15 strings |
|
Storage temperature |
0℃~40℃ |
|
Differential pressure |
Differential pressure at the discharging end (2.5V for monomer) ≤300mV Differential pressure at the charging end (3.65V for monomer)≤300mV |