Description

SP24 Axpert Primo VM III (PF1) 5Kw 48 Volt 5000-48 Off-Grid Island Solar Inverter

– Alternating Current Power 5kw
– Installed Power Panels 5kw
– 48V battery pack support
– Removable LCD control module with multiple communications
– Built-in Bluetooth for mobile monitoring (Android app is available)
– Supports USB On-the-Go function
– Reserved communication port for BMS (RS485, CAN-BUS or RS232) support x Pylontech, SP24 all, others
– Replaceable fan design for ease of maintenance
– Provide load from the grid or PV, even if the battery is not available
– Usage timers and priority of configurable AC / PV outputs
– Selectable high-power charge current
– Selectable input voltage range for home appliances and personal computers
– Compatible with mains power or generator input
– Automatic reboot while AC is recovering
– Cold start function

INVERTER MODEL

 

 

1.5KW

 

 

3KW

 

 

5KW

 

 

Input voltage waveform

 

 

Sinusoidal (AC grid or generator)

Rated input voltage

 

 

230Vac

Low voltage loss

 

 

170Vac±7V (UPS);

90Vac±7V (equipment)

Low return voltage loss

 

 

180Vac±7V (UPS);

100Vac±7V (Appliances)

High voltage loss

 

 

280Vac±7V

High return voltage loss

 

 

270Vac±7V

Max. AC Input Voltage

 

 

300Vac

Nominal input frequency

 

 

50Hz / 60Hz (Auto detection)

Low Frequency Loss

 

 

40±1 Hz

Low return frequency loss

 

 

42±1 Hz

High frequency loss

 

 

65±1 Hz

 

 

High return frequency loss

 

 

63±1 Hz

Output short circuit protection

 

 

Differential switch

Efficiency (Line Mode)

 

 

>95% (Rated R load, fully charged battery)

Transfer duration

 

 

10ms typical (UPS);

20ms typical (appliances);

Output power reduction

 

 

If the AC input voltage drops to 170 V, the output power will be reduced.

INVERTER MODEL

 

 

1.5KW

 

 

3KW

 

 

5KW

 

 

Rated output power

 

 

1.5KVA/1.5KW

3KVA/3KW

5KVA/5KW

Output voltage waveform

 

 

Pure sine wave

Output Voltage Adjustment

 

 

230Vac±5%

Output frequency

 

 

50 Hz

Peak efficiency

 

 

93%

Overload protection

 

 

5s@≥130% load; 10s@105%~130% load

Overload capacity

 

 

2* Rated power for 5 seconds

Rated DC input voltage

 

 

24Vdc

48Vdc

Cold start voltage

 

 

23.0Vdc

46.0Vdc

DC Low Alarm Voltage

 

 

@ load < 50%

23.0Vdc

46.0Vdc

@ load ≥ 50%

22.0Vdc

44.0Vdc

DC Low Alarm Return Voltage

 

 

@ load < 50%

23.5Vdc

47.0Vdc

@ load ≥ 50%

23.0Vdc

46.0Vdc

DC Low Cutoff Voltage

 

 

@ load < 50%

21.5Vdc

43.0Vdc

@ load ≥ 50%

21.0Vdc

42.0Vdc

DC High Voltage Recovery

 

 

32Vdc

62Vdc

DC High cutoff voltage

 

 

33Vdc

63Vdc

No-load consumption

 

 

<35W

<50W

Charging mode AC network

 

 

INVERTER MODEL

 

 

1.5KW

 

 

3KW

 

 

5KW

 

 

Charging algorithm

 

 

3-Step

 

 

AC charging current (max.)

 

 

40Amp (@VI/P=230Vac)

60Amp

(@VI/P=230Vac)

Bulk charging voltage

 

 

Flooded battery

 

 

29,2

58,4

AGM/Gel Battery

 

 

28,2

56,4

Float voltage

 

 

27Vdc

54Vdc

Charge curve

 

 

MPPT Solar Charging Mode

INVERTER MODEL

 

 

1.5KW

 

 

3KW

 

 

5KW

 

 

Max. PV array power

 

 

2000 W

4000W

5000W

Rated PV voltage

 

 

240Vdc

320Vdc

Inrush voltage

 

 

150Vdc +/- 10Vdc

PV array MPPT voltage range

 

 

120~380Vdc

120~450Vdc

Max. PV array open circuit voltage

 

 

400Vdc

500Vdc

Maximum charging current

 

 

(AC charger plus solar charger)

 

 

60A

80Amp

INVERTER MODEL

 

 

1.5KW

 

 

3KW

 

 

5KW

 

 

Operating temperature range

 

 

– 10 °C + 50 °C

Storage temperature

 

 

-15°C~ 60°C

Moisture

 

 

5 – 95% relative humidity (no condensation)

Dimensions (W*L*H), mm

 

 

100 x 280 x 390

115 x 300 x 400

Net weight, kg

 

 

8,5

9

10

Additional information