Voltronic Axpert VM II Premium 5000-48 Off-Grid Island Solar Inverter 5000 Watt 48 Volts

420,20

Description

Voltronic AXPERT VM II Premium 5000-48 Inverter
• AC Power 5 kW
• Supports 48V battery banks
• Installable Panel Power 5 kW
• Pure sine wave solar inverter
• Selectable high-power charge current
• Wide DC input range (up to 500 volts VOC)
• Configurable AC/Solar input priority via LCD settings
• RS485 BMS communication port compatible with DYNESS, LUXPOWER, and PYLONTECH batteries
• Built-in Wi-Fi for mobile monitoring (app available for Android/iOS)

For the Complete Technical Characteristics See the detail below

TECHNICAL SPECIFICATIONS

Table 1 Line Mode Specifications

INVERTER MODEL

1.2KVA


2

.

5KVA

3KVA

5KVA

Input voltage waveform

Sinusoidal (AC mains or generator)

Rated input voltage

230Vac

Low voltage loss

170Vac±7V (UPS);

90Vac±7V (equipment)

Low Return Voltage Drop

180Vac±7V (UPS);

100Vac ± 7V (Equipment)

High Voltage Drop

280Vac±7V

High Return Voltage Drop

270Vac±7V

Max. AC Input Voltage

300Vac

Rated input frequency

50Hz / 60Hz (Auto Detect)

Low Frequency Drop

40±1 Hz

Fall Return Frequency Low

42±1 Hz

High Frequency Fall

65±1 Hz

High Return Voltage Drop

63±1 Hz

Output short circuit protection

Differential

Efficiency (Line Mode)

>95% (Rated load R, battery fully charged)

Transfer duration

10ms typical (UPS);

20ms typical (equipment);

Output power reduction

If the AC input voltage drops to 170 V, the output power will be reduced.

Table 2 Inverter Mode Specifications

INVERTER MODEL

1.2KVA


2

.

5KVA

3KVA

5KVA

Rated output power

1.2KVA/ 1.2KW

2.5KVA/ 2.5KW

3KVA/3KW

5KVA/5KW

Output voltage waveform

Pure sine wave

Output Voltage Adjustment

230Vac±5%

Output frequency

50 Hz

Peak efficiency

93%

Overload protection

5s@≥130% load; 10s@105%~130% load

Overload capacity

2* Rated power for 5 seconds

Rated DC input voltage

12Vdc

24Vdc

48Vdc

Cold start voltage

11.5Vdc

23.0Vdc

46.0Vdc

Low DC alarm voltage

@ load < 50%

11.5Vdc

23.0Vdc

46.0Vdc

@ load ≥ 50%

11.0Vdc

22.0Vdc

44.0Vdc

Low DC Alarm Return Voltage

@ load < 50%

11.7Vdc

23.5Vdc

47.0Vdc

@ load ≥ 50%

11.5Vdc

23.0Vdc

46.0Vdc

Low Cutoff Voltage DC

@ load < 50%

10.7Vdc

21.5Vdc

43.0Vdc

@ load ≥ 50%

10.5Vdc

21.0Vdc

42.0Vdc

DC High Voltage Recovery

15Vdc

31Vdc

62Vdc

DC High cutoff voltage

16Vdc

32Vdc

63Vdc

No-load consumption

<35W

<50W

Table 3 Charge Mode Specifications

AC Grid Load Mode

INVERTER MODEL

1.2KVA


2

.

5KVA

3KVA

5KVA

Charging algorithm

3-Step

AC charging current (max.)

80Amp (@VI/P=230Vac)

100Amp

Bulk charge voltage

Flooded battery

14,6

29,2

58,4

AGM/Gel Battery

14,1

28,2

56,4

Float voltage

13.5Vdc

27Vdc

54Vdc

Charge curve

MPPT Solar Charging Mode

INVERTER MODEL

1.2KVA


2

.

5KVA

3KVA

5KVA

Max. PV array power

2000W

3000W

5000W

Rated PV voltage

240Vdc

320Vdc

Starting voltage

70Vdc +/- 10Vdc

150Vdc +/- 10Vdc

PV array MPPT voltage range

60~300Vdc

60~400Vdc

120~450Vdc

Max. PV array open circuit voltage

350Vdc

450Vdc

500Vdc

Max. Input current

13Amp

18Amp

Maximum charging current

(AC charger plus solar charger)

100Amp

Table 4 General Specifications

INVERTER MODEL

1.2KVA


2

.

5KVA

3KVA

5KVA

Safety certification

THERE IS

Operating temperature range

– 10 °C + 50 °C

Storage temperature

-15 ° C ~ 60 ° C

Moisture

5 – 95% relative humidity (no condensation)

Dimensions (W*L*H), mm

90 x 288 x 357

110 x 288 x 390

120 x 300 x 440

Net weight, kg

6,5

7,0

7,2

10

 

Additional information

Weight 25 kg
Vat Rate

,

Download Documents

Manuale SP24_Axpert_VM_II_Premium_1-5Kw_20230318_ITA

Manual SP24_Axpert_VM_II_Premium_1-5Kw_20230318_EN

Reviews

There are no reviews yet.


Be the first to review “Voltronic Axpert VM II Premium 5000-48 Off-Grid Island Solar Inverter 5000 Watt 48 Volts”