SP24 Primo MKS III 5K-48 5000 Watt 48 Volt Island Photovoltaic Solar Inverter
€601,70
SP24 Primo MKS III (PF1) 5K-48 Island Photovoltaic Solar Inverter
- Power Alternating Current 5kw
• Installable power 5kw panels
• 48V battery pack support
• Pure sine wave solar inverter
• High power selectable charging current
• Wide DC input range up to 450 volts VOC
• Removable LCD control module with multiple communications
• Integrated Bluetooth for mobile monitoring (Android app available)
• Supports USB On-the-Go function
• Communication port reserved for BMS (RS485)
• Selectable input voltage range for household appliances and personal computers
• AC / Solar input priority configurable via LCD setting
• Compatible with mains voltage or generator
• Automatic restart while AC is recovering
• Overload and short circuit protection
• Smart charger design to optimize battery performance
• Cold start function
• Parallel operation with up to 9 units (parallel kit included)
• Operation even without batteries connected
- Description
- Additional information
- Download Documents
- Reviews (0)
Description
SP24 Primo MKS III (PF1) 5K-48 Island Photovoltaic Solar Inverter
- Power Alternating Current 5kw
– Installed Power Panels 5kw
– 48V battery pack support
– Pure sine wave solar inverter
– Selectable high-power charge current
• Wide DC input range up to 450 volts VOC
• Removable LCD control module with multiple communications
– Built-in Wi-fi for mobile monitoring (Android app is available)
• Supports USB On-the-Go function
• Communication port reserved for BMS (RS485)
• Selectable input voltage range for household appliances and personal computers
– AC / Solar input priority configurable via LCD setting
• Compatible with mains voltage or generator
• Automatic restart while AC is recovering
• Overload and short circuit protection
• Smart charger design to optimize battery performance
• Cold start function
• Parallel operation with up to 9 units (parallel kit included)
• Operation even without batteries connected
Table 1 Line Mode Specifications
INVERTER MODEL
|
5KW
|
Input voltage waveform
|
Sinusoidal (AC mains or generator) |
Rated input voltage
|
230Vac |
Low voltage loss
|
170Vac ± 7V (UPS) 90Vac ± 7V (equipment) |
Low return voltage loss
|
180Vac ± 7V (UPS); 100Vac ± 7V (Appliances) |
High voltage loss
|
280Vac ± 7V |
High return voltage loss
|
270Vac ± 7V |
Max. AC input voltage
|
300Vac |
Rated input frequency
|
50Hz / 60Hz (Auto Detect) |
Low frequency loss
|
40 ± 1 Hz |
Low return frequency loss
|
42 ± 1 Hz |
High frequency loss
|
65 ± 1 Hz
|
High return frequency loss
|
63 ± 1 Hz |
Short circuit protection at the output
|
Line mode protection device Battery mode Electronic circuits |
Efficiency (Line Mode)
|
>95% (Rated load R, battery fully charged) |
Transfer duration
|
10ms typical (UPS); 20ms typical (appliances); |
Reduction of output power
If the AC input voltage drops to 95V or 170V depending on the models, the output power will be reduced. |
|
Table 2 Inverter Mode Specifications
INVERTER MODEL
|
5KW
|
Rated output power
|
5KVA / 5KW |
Output voltage waveform
|
Pure sine wave |
Output voltage regulation
|
230Vac ± 5% |
Output frequency
|
60Hz or 50Hz |
Peak efficiency
|
90% |
Overload protection
|
5s @ ≥150% load; 10s @ 110 %~150% load |
Overload capacity
|
2 * Rated power for 5 seconds |
Nominal DC input voltage
|
48Vdc |
Cold start voltage
|
46.0Vdc |
Low DC alarm voltage
|
|
@ load< 20% |
44.0Vdc |
@ 20% ≤ load< 50% |
42.8Vdc |
@ load ≥ 50% |
40.4Vdc |
DC Low Return Voltage Alarm
|
|
@ load< 20% |
46.0Vdc |
@ 20% ≤ load< 50% |
44.8Vdc |
@ load ≥ 50% |
42.4Vdc |
DC Low Voltage cutoff
|
|
@ load< 20% |
42.0Vdc |
@ 20% ≤ load< 50% |
40.8Vdc |
@ load ≥ 50% |
38.4Vdc |
High recovery DC voltage
|
62Vdc |
High DC cutoff voltage
|
64Vdc |
Table 3 Charge Mode Specifications
AC mains charging mode |
|||
INVERTER MODEL
|
5KW
|
||
Charging current (UPS)
@ Nominal input voltage
|
80A |
||
Bulk charge voltage
|
Flooded battery
|
58,4 |
|
AGM / Gel battery
|
56,4 |
||
Float voltage
|
54Vdc |
||
Overload protection
|
64Vdc |
||
Charging algorithm
|
3-Step |
||
Charge curve
|
|
||
Solar entrance |
|||
INVERTER MODEL
|
5KW
|
||
Nominal power
|
5000W |
||
Max. PV array open circuit voltage
|
450Vdc |
||
PV array MPPT voltage range
|
120Vdc ~ 430Vdc |
||
Max. Input current
|
18A |
||
Table 4 General Specifications
INVERTER MODEL
|
5 KW
|
Safety certification
|
THERE IS |
Operating temperature range
|
– 10 ° C + 50 ° C |
Storage temperature
|
-15 ° C ~ 60 ° C |
Humidity
|
5 – 95% relative humidity (non-condensing) |
Dimensions (P * W * H), mm
|
140 x 295 x 468 |
Net weight, kg
|
12 |
.
The product is saleable with vat reduced to 10% only to Italian residents with shipping to italy. In the case of foreign customers, the site will apply the VAT rate of the country of destination
THE FORM CAN BE FOUND HERE
https://www.cercastock.it/repository/_barba_srl_dich_10.pdf
THE PRODUCT CANNOT BE SHIPPED UNTIL THE COMPLETED FORM IS RECEIVED
TO EMAIL ADDRESS moduloiva@solarpower24.it or by fax to 0545030125
Download Documents
Manual Axpert MKS III 5Kw ITA
Manuale Axpert MKS III 5Kw ITA
Manual Axpert MKS III 5Kw EN
Manual Axpert MKS III 5Kw EN
Reviews
There are no reviews yet.