Battery Pack Parameters
No.
|
Items
|
General Parameter
|
Remark
|
|
1 |
Combination method |
15S |
|
|
2 |
Nominal Voltage |
48V |
|
|
3 |
Rated Capacity |
Typical |
150Ah |
|
Minimum |
150Ah |
|||
4 |
Energy |
7200Wh |
|
|
5 |
Factory Voltage |
48~51V |
Mean Operation Voltage |
|
6 |
Voltage at end of Discharge |
37.5~42V |
Discharge Cut-off Voltage |
|
7 |
Voltage at end of Charge |
52.5~55.5V |
Charge Cut-off Voltage |
|
8 |
Standard charge |
Constant Current 30A Constant Voltage see No.7 0.02CA cut-off |
Charge time : Approx 5~6 h |
|
9 |
Limiting current |
20A |
BMS Limited (Charge current is ≥100A to open the current Limit) |
|
10 |
Standard discharge |
Constant current : 30A end voltage see NO.6 |
|
|
11 |
Maximum Continuous Charge Current |
100A |
50ºC≥T≥5ºC |
|
12 |
Maximum Continuous Discharge Current |
100A |
55ºC≥T≥0ºC |
|
13 |
Operation Temperature Range |
Charge:0~55℃ |
60±25%R.H. No matter what mode the battery is in, once the temperature is found to exceed the absolute temperature range, stop charging or discharging immediately |
|
Discharge:–20~60℃ |
||||
14 |
Storage Temperature Range |
Less than 6 months: -10~35℃ |
60±25%R.H. at the shipment state |
|
Less than 3 months: -10~45℃ |
||||
Less than 1 months: -20~55℃ |
||||
15 |
Dimensions(W*D*H) |
610 * 630 * 167mm |
Include case |
|
16 |
Net Weight |
86Kg |
Include case |
|
17 |
Internal Impedance |
≤40m Ω _ |
Internal resistance measured at AC 1KHZ after 50% charge. The measure must uses the new batteries that within one week after shipment and cycles less than 5 times. |
Battery Management System
Function
|
||
Alarm |
Cell over-charge voltage |
Cell charge low temperature |
Cell over-discharge voltage |
Cell charge over temperature |
|
Pack over-charge voltage |
Cell discharge low temperature |
|
Pack over-discharge voltage |
Cell discharge over temperature |
|
Over-current charge |
Environment low temperature |
|
Over-current discharge |
Environment over temperature |
|
Mos over temperature |
|
|
Protection |
Cell over-charge voltage |
Cell charge over temperature |
Cell over-discharge voltage |
Cell discharge low temperature |
|
Pack over-charge voltage |
Cell discharge over temperature |
|
Pack over-discharge voltage |
Environment low temperature |
|
Over-current charge |
Environment over temperature |
|
Over-current discharge |
Short circuit |
|
Mos over temperature |
Fault |
|
Cell charge low temperature |
|
|
Others |
Cell balance function |
|
Communicate function |
||
Total capacity function |
||
Storage history function |
||
Current limiting function |
||
Dry contact function |