SP24 Primo MKS III 5K-48 5000 Watt 48 Volt Island Photovoltaic Solar Inverter
€574,20
SP24 Primo MKS III (PF1) 5K-48 Island Photovoltaic Solar Inverter
- Power Alternating Current 5kw
• Installable power 5kw panels
• 48V battery pack support
• Pure sine wave solar inverter
• High power selectable charging current
• Wide DC input range up to 450 volts VOC
• Removable LCD control module with multiple communications
• Integrated Bluetooth for mobile monitoring (Android app available)
• Supports USB On-the-Go function
• Communication port reserved for BMS (RS485)
• Selectable input voltage range for household appliances and personal computers
• AC / Solar input priority configurable via LCD setting
• Compatible with mains voltage or generator
• Automatic restart while AC is recovering
• Overload and short circuit protection
• Smart charger design to optimize battery performance
• Cold start function
• Parallel operation with up to 9 units (parallel kit included)
• Operation even without batteries connected
- Description
- Additional information
- Download Documents
- Reviews (0)
Description
SP24 Primo MKS III (PF1) 5K-48 Island Photovoltaic Solar Inverter
- Power Alternating Current 5kw
– Installed Power Panels 5kw
– 48V battery pack support
– Pure sine wave solar inverter
– Selectable high-power charge current
• Wide DC input range up to 450 volts VOC
• Removable LCD control module with multiple communications
– Built-in Wi-fi for mobile monitoring (Android app is available)
• Supports USB On-the-Go function
• Communication port reserved for BMS (RS485)
• Selectable input voltage range for household appliances and personal computers
– AC / Solar input priority configurable via LCD setting
• Compatible with mains voltage or generator
• Automatic restart while AC is recovering
• Overload and short circuit protection
• Smart charger design to optimize battery performance
• Cold start function
• Parallel operation with up to 9 units (parallel kit included)
• Operation even without batteries connected
Table 1 Line Mode Specifications
|
INVERTER MODEL
|
5KW
|
|
Input voltage waveform
|
Sinusoidal (AC mains or generator) |
|
Rated input voltage
|
230Vac |
|
Low voltage loss
|
170Vac ± 7V (UPS) 90Vac ± 7V (equipment) |
|
Low return voltage loss
|
180Vac ± 7V (UPS); 100Vac ± 7V (Appliances) |
|
High voltage loss
|
280Vac ± 7V |
|
High return voltage loss
|
270Vac ± 7V |
|
Max. AC input voltage
|
300Vac |
|
Rated input frequency
|
50Hz / 60Hz (Auto Detect) |
|
Low frequency loss
|
40 ± 1 Hz |
|
Low return frequency loss
|
42 ± 1 Hz |
|
High frequency loss
|
65 ± 1 Hz
|
|
High return frequency loss
|
63 ± 1 Hz |
|
Short circuit protection at the output
|
Line mode protection device Battery mode Electronic circuits |
|
Efficiency (Line Mode)
|
>95% (Rated load R, battery fully charged) |
|
Transfer duration
|
10ms typical (UPS); 20ms typical (appliances); |
|
Reduction of output power
If the AC input voltage drops to 95V or 170V depending on the models, the output power will be reduced. |
|
Table 2 Inverter Mode Specifications
|
INVERTER MODEL
|
5KW
|
|
Rated output power
|
5KVA / 5KW |
|
Output voltage waveform
|
Pure sine wave |
|
Output voltage regulation
|
230Vac ± 5% |
|
Output frequency
|
60Hz or 50Hz |
|
Peak efficiency
|
90% |
|
Overload protection
|
5s @ ≥150% load; 10s @ 110 %~150% load |
|
Overload capacity
|
2 * Rated power for 5 seconds |
|
Nominal DC input voltage
|
48Vdc |
|
Cold start voltage
|
46.0Vdc |
|
Low DC alarm voltage
|
|
|
@ load< 20% |
44.0Vdc |
|
@ 20% ≤ load< 50% |
42.8Vdc |
|
@ load ≥ 50% |
40.4Vdc |
|
DC Low Return Voltage Alarm
|
|
|
@ load< 20% |
46.0Vdc |
|
@ 20% ≤ load< 50% |
44.8Vdc |
|
@ load ≥ 50% |
42.4Vdc |
|
DC Low Voltage cutoff
|
|
|
@ load< 20% |
42.0Vdc |
|
@ 20% ≤ load< 50% |
40.8Vdc |
|
@ load ≥ 50% |
38.4Vdc |
|
High recovery DC voltage
|
62Vdc |
|
High DC cutoff voltage
|
64Vdc |
Table 3 Charge Mode Specifications
|
AC mains charging mode |
|||
|
INVERTER MODEL
|
5KW
|
||
|
Charging current (UPS)
@ Nominal input voltage
|
80A |
||
|
Bulk charge voltage
|
Flooded battery
|
58,4 |
|
|
AGM / Gel battery
|
56,4 |
||
|
Float voltage
|
54Vdc |
||
|
Overload protection
|
64Vdc |
||
|
Charging algorithm
|
3-Step |
||
|
Charge curve
|
|
||
|
Solar entrance |
|||
|
INVERTER MODEL
|
5KW
|
||
|
Nominal power
|
5000W |
||
|
Max. PV array open circuit voltage
|
450Vdc |
||
|
PV array MPPT voltage range
|
120Vdc ~ 430Vdc |
||
|
Max. Input current
|
18A |
||
Table 4 General Specifications
|
INVERTER MODEL
|
5 KW
|
|
Safety certification
|
THERE IS |
|
Operating temperature range
|
– 10 ° C + 50 ° C |
|
Storage temperature
|
-15 ° C ~ 60 ° C |
|
Humidity
|
5 – 95% relative humidity (non-condensing) |
|
Dimensions (P * W * H), mm
|
140 x 295 x 468 |
|
Net weight, kg
|
12 |
Download Documents
Manual Axpert MKS III 5Kw ITA
Manual Axpert MKS III 5Kw EN






Reviews