Voltronic Axpert VM III TWIN 6000watt 48V Off-Grid Inverter
€521,40
- Description
- Additional information
- Download Documents
Description
Voltronic Axpert VM III TWIN 6Kw 48V 6000-48 Inverter Solar Island Off Grid
– Alternating Current Power 6kw
• Installable power 6kw panels
– 48V battery pack support
– Removable LCD control module with multiple communications
– Built-in Wi-Fi for mobile monitoring (Android/Iphone app available)
– Supports USB On-the-Go function
– Reserved communication port for BMS (RS485) support x Pylontech US2000/3000, Yilink 50/100/150Ah 48v, SP24 50/100Ah
– Replaceable fan design for ease of maintenance
– Provide load from the grid or PV, even if the battery is not available
– Usage timers and priority of configurable AC / PV outputs
– Selectable high-power charge current
– Selectable input voltage range for home appliances and personal computers
– Compatible with mains power or generator input
– Automatic reboot while AC is recovering
– Cold start function
TECHNICAL SPECIFICATIONS
Table 1 Line Mode Specifications
|
INVERTER MODEL |
4KW |
6KW |
|
Input voltage waveform |
Sinusoidal (AC mains or generator) |
|
|
Rated input voltage |
230Vac |
|
|
Low voltage loss |
170Vac±7V (UPS); 90Vac±7V (equipment) |
|
|
Low Return Voltage Drop |
180Vac±7V (UPS); 100Vac ± 7V (Equipment) |
|
|
High Voltage Drop |
280Vac±7V |
|
|
High Return Voltage Drop |
270Vac±7V |
|
|
Max. AC Input Voltage |
300Vac |
|
|
Rated input frequency |
50Hz / 60Hz (Auto Detect) |
|
|
Low Frequency Drop |
40±1 Hz |
|
|
Low Return Voltage Drop |
42±1 Hz |
|
|
High Frequency Drop |
65±1 Hz |
|
|
High Return Voltage Drop |
63±1 Hz |
|
|
Output short circuit protection |
Differential switch |
|
|
Efficiency (Line Mode) |
>95% (Rated load R, battery fully charged) |
|
|
Transfer duration |
10ms typical (UPS); 20ms typical (equipment); |
|
|
Output power reduction If the AC input voltage drops to 170 V, the output power will be reduced. |
||
Table 2 Inverter Mode Specifications
|
INVERTER MODEL |
4KW |
6KW |
|
Rated output power |
4KVA/4KW |
6KVA/6KW |
|
Output voltage waveform |
Pure sine wave |
|
|
Output Voltage Adjustment |
230Vac±10% |
|
|
Output frequency |
50 Hz |
|
|
Peak efficiency |
93% |
|
|
Overload protection |
5s@≥110% load; 10s@105~110% load |
|
|
Overload capacity |
2* Rated power for 5 seconds |
|
|
Max. AC output current |
30Amp |
40Amp |
|
Nominal DC input voltage |
24Vdc |
48Vdc |
|
Cold start voltage |
23.0Vdc |
46.0Vdc |
|
Low DC alarm voltage |
23.0Vdc 22.0Vdc |
46.0Vdc 44.0Vdc |
|
@ load < 50% |
||
|
@ load ≥ 50% |
||
|
DC Low Alarm Return Voltage |
23.5Vdc 23.0Vdc |
47.0Vdc 46.0Vdc |
|
@ load < 50% |
||
|
@ load ≥ 50% |
||
|
DC Low Cutoff Voltage |
21.5Vdc 21.0Vdc |
43.0Vdc 42.0Vdc |
|
@ load < 50% |
||
|
@ load ≥ 50% |
||
|
DC High Voltage Recovery |
32Vdc |
62Vdc |
|
High DC cutoff voltage |
33Vdc |
63Vdc |
|
No-load consumption |
<40W |
<55W |
Table 3 Charge Mode Specifications
|
AC Grid Load Mode |
|||
|
INVERTER MODEL |
4KW |
6KW |
|
|
Charging algorithm |
3-Step |
||
|
AC charging current (max.) |
100Amp (@VI/P=230Vac) |
||
|
Bulk charge voltage |
Lead-acid battery |
29.2Vdc |
58,4 |
|
AGM/Gel Battery |
28.2Vdc |
56,4 |
|
|
Float voltage |
27Vdc |
54Vdc |
|
|
Charge curve |
|
||
|
MPPT Solar Charging Mode |
|||
|
INVERTER MODEL |
4KW |
6KW |
|
|
Max. PV array power |
5000W |
6000W |
|
|
Max. PV Current |
27A |
||
|
Rated PV voltage |
320Vdc |
360Vdc |
|
|
Starting voltage |
60Vdc +/- 10Vdc |
||
|
PV array MPPT voltage range |
60Vdc~450Vdc |
||
|
Max. PV array open circuit voltage |
500Vdc |
||
|
Maximum charging current (AC charger plus solar charger) |
120Amp |
||
Table 4 General Specifications
|
INVERTER MODEL |
4KW |
6KW |
|
Operating temperature range |
– 10 °C + 50 °C |
|
|
Storage temperature |
-15 ° C ~ 60 ° C |
|
|
Moisture |
5 – 95% relative humidity (no condensation) |
|
|
Dimensions (W*L*H), mm |
115 x 300 x 435 |
|
|
Net weight, kg |
9 |
10 |