SP24 Axpert MAX DUPLEX 11000-48 Inverter 11.0kw 48 volts
€1.095,60
- Description
- Additional information
- Download Documents
Description
SP24 Axpert MAX DUPLEX 11000-48 Inverter 11.0kw 48 volts off grid island Photovoltaic inverter for off grid hybrid island system
– Two independent AC inputs (Grid and/or Generator)
• Status indication with RGB lights
• Integrated Wi-Fi for mobile monitoring (Android / iOS app available)
• Supports USB On-the-Go function
• Communication port reserved for BMS (RS485)
• Replaceable fan design for ease of maintenance
• Battery independent design
• Configurable timer and priority of use of the AC / PV output
– Selectable high-power charge current
– Selectable input voltage range for home appliances and personal computers
– Communication with BMS battery Pylontech US2000/US3000, SP24, Yilink, Voltronic, UFO Power
– Compatible with mains or generator input
– Built-in dust kit
– Optional DC output for DC fan, LED bulb, router and so on.
– Single-phase with dual 5500w MPPT regulator-Parallel operation with 6 units
TECHNICAL SPECIFICATIONS
Table 1 Line Mode Specifications
MODEL |
11KW |
Input voltage waveform |
Sinusoidal (AC mains or generator) |
Rated input voltage |
230Vac |
Low voltage loss |
170Vac ± 7V (UPS) 90Vac ± 7V (equipment) |
Low Return Voltage Drop |
180Vac ± 7V (UPS); 100Vac ± 7V (Equipment) |
High Voltage Drop |
280Vac ± 7V |
High Return Voltage Drop |
270Vac ± 7V |
Max. AC input voltage |
300Vac |
Current Max. AC input |
60A |
Max. output current for second port |
40A |
Rated input frequency |
50Hz / 60Hz (Auto Detect) |
Low Frequency Drop |
40 ± 1 Hz |
Low Return Voltage Drop |
42 ± 1 Hz |
High Frequency Drop |
65 ± 1 Hz |
High Return Voltage Drop |
63 ± 1 Hz |
Short circuit protection at the output |
Line Mode: RCD (70A) Battery mode: Electronic Circuits |
Efficiency (Line Mode) |
>95% (Rated load R, battery fully charged) |
Transfer duration |
10ms typical (UPS); 20ms typical (equipment); |
Output power reduction: If the AC input voltage drops below 170V, the output power will be reduced. |
|
Table 2 Inverter Mode Specifications
MODEL |
11KW |
Rated output power |
11000W |
Output voltage waveform |
Pure sine wave |
Output voltage regulation |
230Vac ± 5% |
Output frequency |
60Hz or 50Hz |
Peak efficiency |
93% |
Overload protection |
100ms@≥180% load;5s@≥120% load; 10s@105~120 load |
Overload capacity |
2 * Rated power for 5 seconds |
Alarm voltage DC Low |
|
@ load< 20% |
46.0Vdc |
@ 20% ≤ load< 50% |
42.8Vdc |
@ load ≥ 50% |
40.4Vdc |
Alarm Return Voltage DC Low |
|
@ load< 20% |
48.0Vdc |
@ 20% ≤ load< 50% |
44.8Vdc |
@ load ≥ 50% |
42.4Vdc |
Low DC cutoff voltage |
|
@ load< 20% |
44.0Vdc |
@ 20% ≤ load< 50% |
40.8Vdc |
@ load ≥ 50% |
38.4Vdc |
DC High Recovery Voltage |
61Vdc |
DC cutoff voltage High |
63Vdc |
DC voltage accuracy |
|
THDV |
<5% for linear load,< 10% for non-linear load @ rated voltage |
DC offset |
≦100 mV |
Power limitation If the battery voltage is less than 55Vdc, the output power will be reduced. If the connected load is greater than this reduced power, the output AC voltage will decrease until the output power is reduced to this reduced power. The minimum AC output voltage is the output voltage setting-10V. |
|
Table 3 Charge Mode Specifications
AC Grid Load Mode |
|||
MODEL |
11KW |
||
Charging current (UPS) @ Nominal input voltage |
150A |
||
Bulk charge voltage |
Lead-acid battery |
58.4Vdc |
|
AGM / Gel battery |
56.4Vdc |
||
Charging float voltage |
54Vdc |
||
Overload protection |
63Vdc |
||
Charging algorithm |
3-Step |
||
Charge curve |
|
||
Solar entrance |
|||
MODEL |
11KW |
||
Nominal power |
11000W |
||
Max. PV array open circuit voltage |
500Vdc |
||
PV array MPPT voltage range |
90Vdc ~ 450Vdc |
||
Max. Input current |
27A x 2 (MAX 40A) |
||
Max. Charging current |
150A |
||
Starting voltage |
80 V +/- 5Vdc |
||
Power limitation |
|
||
Table 4 General Specifications
MODEL |
11KW |
Safety Certification |
THERE IS |
Operating temperature range |
– 10 ° C + 50 ° C |
Storage temperature |
-15 ° C ~ 60 ° C |
Humidity |
5 – 95% relative humidity (non-condensing) |
Dimensions (P * L * H), mm |
147.4x 432.5 x 553.6 |
Net weight, kg |
18,4 |
Table 5 Parallel specifications
Nr. max. in parallel |
6 |
Circulation current under no-load conditions |
Max. 2A |
Power imbalance ratio |
<5% @ 100% load |
Parallel communication |
CAN |
Transfer time in parallel mode |
Max.50ms |
Parallel Kit |
YES |
Note: The parallel function will be disabled if only PV power is available
Download Documents
Manual SP24_Axpert_MAX__DUPLEX_11KW ITA
Manual SP24_Axpert_MAX__DUPLEX_11KW ENG
Manual SP24_Axpert_MAX__DUPLEX_11KW DE