SP24 Axpert VM III TWIN 6000watt 48V Off-Grid Inverter
€569,80
- Description
- Additional information
- Download Documents
Description
SP24 Axpert VM III TWIN 6Kw 48V 6000-48 Inverter Solar Island Off Grid
– Alternating Current Power 6kw
• Installable power 6kw panels
– 48V battery pack support
• Removable LCD control module with multiple communications
– Built-in Wi-Fi for mobile monitoring (Android/Iphone app available)
• Supports USB On-the-Go function
– Reserved communication port for BMS (RS485) support x Pylontech US2000/US3000/US5000, Yilink 50/100/150Ah 48v, SP24 50/100Ah
• Replaceable fan design for ease of maintenance
• Supply the load from the grid or the PV, even if the battery is not available
• Use timer and priority of AC / PV configurable outputs
– Selectable high-power charge current
• Selectable input voltage range for household appliances and personal computers
• Compatible with mains supply or generator input
• Automatic restart while AC is recovering
• Cold start function
TECHNICAL SPECIFICATIONS
Table 1 Line Mode Specifications
INVERTER MODEL |
4KW |
6KW |
Input voltage waveform |
Sinusoidal (AC mains or generator) |
|
Rated input voltage |
230Vac |
|
Low voltage loss |
170Vac ± 7V (UPS); 90Vac ± 7V (equipment) |
|
Low Return Voltage Drop |
180Vac ± 7V (UPS); 100Vac ± 7V (Equipment) |
|
High Voltage Drop |
280Vac ± 7V |
|
High Return Voltage Drop |
270Vac ± 7V |
|
Max. AC input voltage |
300Vac |
|
Rated input frequency |
50Hz / 60Hz (Auto Detect) |
|
Low Frequency Drop |
40 ± 1 Hz |
|
Low Return Voltage Drop |
42 ± 1 Hz |
|
High Frequency Drop |
65 ± 1 Hz |
|
High Return Voltage Drop |
63 ± 1 Hz |
|
Short circuit protection at the output |
Differential switch |
|
Efficiency (Line Mode) |
>95% (Rated load R, battery fully charged) |
|
Transfer duration |
10ms typical (UPS); 20ms typical (equipment); |
|
Reduction of output power If the AC input voltage drops to 170V, the output power will be reduced. |
Table 2 Inverter Mode Specifications
INVERTER MODEL |
4KW |
6KW |
Rated output power |
4KVA/4KW |
6KVA/6KW |
Output voltage waveform |
Pure sine wave |
|
Output voltage regulation |
230Vac±10% |
|
Output frequency |
50 Hz |
|
Peak efficiency |
93% |
|
Overload protection |
5s@≥110% load; 10s@105~110% load |
|
Overload capacity |
2 * Rated power for 5 seconds |
|
Max. AC output current |
30Amp |
40Amp |
Nominal DC input voltage |
24Vdc |
48Vdc |
Cold start voltage |
23.0Vdc |
46.0Vdc |
Low DC alarm voltage |
23.0Vdc 22.0Vdc |
46.0Vdc 44.0Vdc |
@ load< 50% |
||
@ load ≥ 50% |
||
DC Low Return Voltage Alarm |
23.5Vdc 23.0Vdc |
47.0Vdc 46.0Vdc |
@ load< 50% |
||
@ load ≥ 50% |
||
DC Low Voltage cutoff |
21.5Vdc 21.0Vdc |
43.0Vdc 42.0Vdc |
@ load< 50% |
||
@ load ≥ 50% |
||
DC High Recovery Voltage |
32Vdc |
62Vdc |
High DC cutoff voltage |
33Vdc |
63Vdc |
Consumption without load |
<40W |
<55W |
Table 3 Charge Mode Specifications
AC Grid Load Mode |
|||
INVERTER MODEL |
4KW |
6KW |
|
Charging algorithm |
3-Step |
||
Charging current AC (max.) |
100Amp (@V I / P = 230Vac) |
||
Bulk charge voltage |
Lead-acid battery |
29.2Vdc |
58,4 |
AGM / Gel battery |
28.2Vdc |
56,4 |
|
Float voltage |
27Vdc |
54Vdc |
|
Charge curve |
|
||
MPPT Solar Charge Mode |
|||
INVERTER MODEL |
4KW |
6KW |
|
Max. PV array power |
5000W |
6000W |
|
Max. PV Current |
27A |
||
Nominal PV voltage |
320Vdc |
360Vdc |
|
Starting voltage |
60Vdc +/- 10Vdc |
||
PV array MPPT voltage range |
60Vdc~450Vdc |
||
Max. PV array open circuit voltage |
500Vdc |
||
Maximum charge current (AC charger plus solar charger) |
120Amp |
Table 4 General Specifications
INVERTER MODEL |
4KW |
6KW |
Operating temperature range |
– 10 ° C + 50 ° C |
|
Storage temperature |
-15 ° C ~ 60 ° C |
|
Humidity |
5 – 95% relative humidity (non-condensing) |
|
Dimensions (P * W * H), mm |
115 x 300 x 435 |
|
Net weight, kg |
9 |
10 |